Home > Products > Fireproof cable > SQBTRG
Mineral-insulated Metal sheath Flexible Fire-proof Cable

Mineral-insulated Metal sheath Flexible Fire-proof Cable

Description

1.Product composition

SQBTRG is made up of copper stranded conductor、mica tape fireproofing、mineral compounds、aluminum sheath and LSZH sheath.

Rated Voltage 0.6/1KV(Um=1.2KV) Mineral-insulated Metal sheath Flexible Fire-proof Cable.

Type

Name

Size(mm2)

Cores

 

SQBTRG

 

Mineral-insulated Metal sheath Flexible Fire-proof Cable.

2.5-6

3-61

2.5-240

2-5

10-300

1

 

 

2.Product code 

SQ----------------------Sanqi
 B------------------------Mineral-insulated
 T-------------------------Copper conductor
 R-------------------------Flexible
 G-------------------------Stainless steel
 
 Example for product representation
 Mineral-insulated Metal sheath Flexible Fire-proof Cable、rated voltage0.6/1kv、4cores、cross section95mm2,expressed as:SQBTRG0.6/1KV,4*95
 Mineral-insulated Metal sheath Flexible Fire-proof Cable、rated voltage0.6/1kv、1core、cross section240mm2,expressed as:SQBTRG0.6/1KV,1*240


3.Product features  

 SQBTRG can still keep the fire circuit in normal operation for a certain time after the fire. It’s great helpful for rescue efforts. SQBTRG passed C、W、Z test by BS6387、BS8491--950℃,180mins fire test,650℃ spray test,950℃ mechanical impact test.


4.Product construction 

Environmental material--Low smoke zero halogen during burning
 High mechanical strength--Mineral-insulated Metal sheath Flexible Fire-proof Cable is sturdy and durable, better than steel tape armor under fire conditions.
 High overload capacity-The overload capacity is better than regular YJV cable because of the insulation is used heat resisting(800℃)mica tape and mineral compounds.
 Corrosion resistance—Sheath of SQBTRG is of high corrosion resistance. It’s still safe even our cable installed in place that are vulnerable to chemical corrosion or serious industrial pollution, usually don’t have to take other additional protection.
 Easy installation—The cable can be delivered in coils as per customer's demand on length. SQBTRG can install by regular laying method without midterm splice and specified terminal.

 

5.Product standard and specification

 


Items

GB/T

IEC

DIN VDE

BS

Levels of insulation and
     Withstand voltage

 

12706

 

60502

 

 

Test of burning and mechanical

 

 

 

 

6027

 

Test of flame spread

 

18380.3

 

60332-3

 

0472

 

 

Test of Smoke emission

 

17651.2

 

61034-2

 

0472

 

 

Test of Circuit integrity

 

19666.6

 

60331

 

0472

 

 

Test of halogen content

 

17650.2

 

60754-2

 

0472

 

6387

Burning test of electrical cable system

 

 

 

4102

 



6.Test standard

Test standard of BS6387、BS8491:Design specification of SQBTRG is strictly followed by BS6387、BS8491 and IEC. These specifications had been passed by specialized test of National Fire Administration and SECRI.


Test Item

BS6387、BS8491

GB/T 12666.6

IEC60331

 

 

Burning

 

A
     650+40℃、180min
     B
     750+40℃、180min
     C
     950+40℃、180min
     S
     950+40℃、180min

 

A
       950℃-1000℃、90min

B
       750℃-850℃、90min

 

 

750℃、3h

 

Spray

W:650+40℃
     Burning 15mins first
     Then burning and spray 15min

 

None

 

None

 

Mechanical impact

X:
     650+40℃、15min
     Y:
     750+40℃、15min
     Z:
     950+40℃、15min/30times

 

 

None

 

 

None



7.Parameter table of outer diameter and weight

 


8.Ampacity table

(Environment temperature 40℃, operating temperature 90℃)
  


9. Applications


     Site

Utility system

Necessary emergency public facilities

Fire alarm, smoke regulators, smoke evacuation, audible alarm, CCTV, emergency lighting, spray control, emergency power supply, control centers, life-saving escalators, fire alarm service telephones

Public buildings

General lighting and power systems, emergency power supply, fire alarm and security systems, main trunk circuits

Airports

General lighting and power systems, emergency power supply, fire protection, public places, CCTV

Railway tunnels, public tunnels

General lighting, fire alarm, emergency lighting, smoke evacuation, security duty rooms

Subways

General lighting, emergency lighting, fire protection, CCTV

General lighting systems

Emergency lighting circuits, emergency broadcast lines

Parking lots

General lighting, fire alarm, emergency lighting, smoke extraction, security duty rooms

Financial buildings

Emergency lighting, fire protection, computer information centers, security system control centers

Hospitals

Emergency lighting, emergency power supply, rescue center power supply, fire evacuation

Building exterior

looped network, safety lighting, escalators, emergency stop control systems, fire detection, smoke evacuation

Ancient buildings under repair

Lighting systems, fire alarm, fire fighting system

Hotels

General lighting and power, fire alarm, emergency lighting, bedroom lighting and power, trunk lines in main distribution rooms

Department stores

General lighting and power, emergency lighting, secure circuits in public places

Equipment manufacture

Assembly lines for machinery and equipment

Circuits with explosible gas

The solid structure and metal sheath of mineral insulated cable can avoid propagation among the equipment through liquid, gas and flame.

Sturdy buildings

Main and branch circuits distribution systems, underground main circuit systems

Transport hubs

Public lighting, fire emergency lighting, emergency lighting termination and display indication

Water treatment systems

General lighting, emergency lighting, fire protection

Transformer substation systems

General lighting and power circuits, emergency lighting, fire alarm and security systems