Home > Products > TBM cable
Description

Voltage 

150/750、600/1000V or below


Standard 

According to customer’s requirement


Features

1.The maximum rated temperature of cable conductor is 90°C.

2.Short circuit of conductor(the longest duration of no more than 5 seconds) temperature does not exceed 250°C.

3.Cable allows minimum ambient temperature: UGEFP type: -15°C; UGEFHP type: -33°C.

4.Cold resistance 

5.Used for open pit and underground 

6.Widely used in subway,railway etc 

7.EPR insulated 

8.Cable bending radius: 

Fixed equipment 6D; 

In free way connection 10D; 

Pay-off and wind-up with cable reel 12D; 

(Note:D is the diameter of the cable).


Applications 

It is suitable for shield machine and other heavy equipment in the open-pit mine or underground with rated voltage up to and including 12/20KV.Wildly used in tunnel project of subway ,railway,road,etc.


Temperature 

1.Min ambient temperature 

Type UGEFP -15℃ 

Type UGEFHP(cold resistance) -30℃

2.Max conductor temperature

At normal operation 90℃ 

Short circuit operation (5s maximum duration) 250℃ 

3.Min bending radius 

Fixed installation 6XD 

Flexible use 10XD 

Guide wheel use 15XD 

(note:D is for outer diameter of cable)


Package 

In coil, steel and wooden reel, steel reel, wooden reel.

Type,description and technical performance


Type,description and technical performance


     Type
RatedVoltage(Uo/U)KVDesignation
UGEFP3.6/66/66/108.7/108.7/1512/2014/25TBM Cable(For open pit usage)
UGEFHP3.6/66/66/108.7/108.7/1512/2014/25Cold resistant TBM Cable(For open pit)

Temperature(moving installation)-35℃ to 80℃

Bending radius 7.5×D
Temperature(fixed installation)-45℃ to 95℃

Bending radius5×D
Rated voltage150/750、600/1000V
Test voltage3500V
Oil resistanceexcellent
ConductorVDE 0295/IEC 60228, 5 glass
Insulation materialspecial PVC compound
strandingStranding in layers or rope-lay stranding
fillerKevlar or jute rope filler
Core identificationColored or white number code in the black surface
Tensile strengtha high tensile core in the center reinforced
Level of fire retardantB
Intermediate coatingNon-woven braid reinforced
Outer sheathHigh oil/pressure/abrasion resistant
ShieldNote(if shielded, the density must be over 85% to guarantee normal use)


3.6/6KV TBM Cable


     Cores×
     Cross-section(mm2)
Approx.Outer diameter(mm)20°CCoreInsulationResistance≥MΩ•kmApprox.weight
     (kg/km)
3×25+3×1048.0-52.04004245
3×35+3×1051.0-56.03604828
3×50+3×1656.7-61.73205670
3×70+3×1661.2-66.22807177
3×95+3×1667.5-72.52508337
3×120+3×2570.7-75.72309655
3×150+3×2575.1-80.121011661
3×185+3×3581.2-86.219013092


6/6 6/10KV TBM Cable


     Cores×
     Cross-section(mm2)
Approx.outer diameter(mm)20°CCoreInsulationResistance≥MΩ•kmApprox.weight(kg/km)
3×10+1×1048.9-52.95503500
3×16+1×1653.1-58.15003834
3×25+3×1049.7-54.74504087
3×35+3×1054.5-59.54004979
3×50+3×1658.4-63.43505972
3×70+3×1662.9-67.93107134
3×95+3×1669.2-74.22808695
3×120+3×2572.5-77.526010096
3×150+3×2578.6-83.623011917
3×185+3×3582.9-87.922013721


8.7/10KV 8.7/15KV


     Cores×
     Cross-section(mm2)
Approx.outer diameter(mm)20°CCoreInsulationResistance≥MΩ•kmApprox.weight(kg/km)
3×16+1×1658.5-63.56104648
3×25+3×1056.2-61.25505168
3×35+3×1059.2-64.25005861
3×50+3×1663.1-68.14407166
3×70+3×1669.5-74.53908771
3×95+3×1674.0-79.035010126
3×120+3×2579.0-84.033011827
3×150+3×2583.3-88.330013554
3×185+3×3587.6-93.628015489
Chat Now